Firmware relase notes: 0.17 20241028 If using Dual RF Head, you could get in a position where the device would stop communicating with the PC (would need a factory reset) (if min and max voltages for FWD and/or REF were equal) 0.16 20241012 If using Dual RF Head, it is possible to use only the forward (or reflected) port to get power indication. 0.15 20241001 Added "I/O names" to the device. This lets you "name" the different I/O signals with "easy to remember" names (instead of just "AI1", "DO1" etc) 0.14 20240822 Added support for 1wire based humidity sensor FAN commands via socket connection, setting fan speed(s) is the minimum speed the fan operates at. If fan controller calculates higher speed than set with these commands, the fan controller takes precedence. 0.13 20240728 Better handling of idle socket (abandoned) socket connections 0.12 20240724 Added broadcast feature. REPAM listens on broadcast 255.255.255.255 port 1901 for a specific message. If message is received, REPAM will reply with its IP, Port, FW version and uptime. This makes it easy to find REPAM devices in the network. Added CPULOAD to status message 0.11 20240711 Added failsafe for fan controllers, if temp sensor gets disconnected etc, fans will run with high speed Possible to update firmware via HTTP GET triggered by PAMonitor or REPAM Monitor (as well as FTP GET command via netcat) "Reset to factory" function, keep button on PCB pressed for 3 seconds and all settings will revert to factory (except calibration data) Added "IPCONFIG" JSON, allows network settings to be set from remote Added "ALARMACK" JSON to reset ALARM indicator. ALARM field in status message changed to 0=no alarm, 1=alarm not active but have been, 2=alarm active 0.10 20240617 Initial version REPAMMonitor: 1.0.0.4 202410xx The main window and the settings windows can be resized and scrolled for users with smaller monitors (Thanks Dave KG0D) 1.0.0.3 20241001 If started without argument "REPAMMonitor.cfg" will be used for configuration Added humidity info/configuration Added "I/O name" settings (works from REPAM FW 0.15 and forward), here you can name the different I/O signals. Will be stored in the connected REPAM device. 1.0.0.1 20240617 Initial version PAMonitor: 1.0.0.7 202410xx New menu item, "Stay on top", if enabled application will stay on top of other windows 1.0.0.6 20241001 If started without argument "PAMonitor.cfg" will be used for configuration When going into settings menu, the "I/O names" will be downloaded (works from REPAM FW 0.15 and forward) from the connected REPAM module and shown in the selection boxes. 1.0.0.5 20240822 Added humidity info 1.0.0.4 20240811 Added "PSU On" DO setting. This (if defined) defines one of the relay outputs (DO1..DO6) as "power supply on" outputs. When pressing "Power on" this output will go on, when pressing the button to power off, this output will go off. Can control a relay that switches the main HV supply on/off. 1.0.0.3 20240809 Added "PSUOnDO" settings, this can make an relay (DO) output act as a switch for the HV supply. Will switch on when "PWR ON" pressed and off when power is switched off again. 1.0.0.3 20240803 Added new setting "Update delay (mSec)", this allows you to specify the delay between each update of the data in PAMonitor. This enables you to throttle the update rate if the PC running PAMonitor is heavily loaded. Default is 40 mSec (25 updates/second) 1.0.0.2 20240724 Added handling of Alarms, possible to define voice messages for each alarm. Added menuitem "Open alarm file", this opens the alarm file in notepad 1.0.0.1 20240617 Initial version